V-Chek 2019-nCoV Ag Rapid Test Kit (Nasal)  (1 Test)

This V-Chek test is used for the in vitro qualitative detection of 2019-nCoV antigen. It is an immunochromatography sandwich assay and intended to detect 2019-nCoV N-protein antigen in human nasal (NS) swab specimens. This kit can be used for individuals with or without symptoms or other epidemiological reasons to suspect COVID-19 infection.

Why choose the V-Chek test?

  • Simple and easy to use
  • Sensitivity of result more than 95%
  • Nasal specimen for a comfortable testing experience

The V-Chek 2019-nCoV Ag Rapid Test Kit had received conditional approval for importation and distribution from Medical Device Authority.
MDA Conditional Approval Ref: (77) MDA.600-1/6/27

Please note: this product is currently authorized for sale or distribution in Malaysia. Referring to MDA requirement, it is strictly forbidden for individuals to sell Covid-19 RTK (self-test).

V-chek Nasal – Instruction for Use

Unpeel the pouch and insert nasal swab into 2-3 cm up your nostril. Rotate the swab more than 5 times in both nostrils.  

Immerse the swab into buffer tube. Rotate the swab 10 times and squeeze the liquid from swab before removing the swab. Screw the drip cap and break off the tip of the cap.

Add 3 drops to the sample well and start the time. As the test begins to work, you will see the color move across the result window in the center of the test cassette.

Read the result at 15 minutes. Do not read the result after 20 minutes.

Download the V-chek Nasal Instruction for Use Here

Register to Check Your Lot Number

Frequently Asked Questions (FAQ)

What is the accuracy of the test?

Is collecting Covid-19 sample using nasal swab painful?

When should I use V-Chek Test?

Can I swab one nostril only?

Can I swab my throat instead of my nose for testing?

What should I do if one of the accessories of the test kit is missing from the test package?

What should I do as I spilled some extraction buffer?

What does a negative test result mean?

What does an invalid test result mean?

What Does My Results Mean?

How to read your V-Chek Test Kit Results

  • Read the result at 15 minutes
  • Any negative result read before 15 minutes could be a false negative result
  • Any positive result read after 20 minutes could be a false positive result

Positive (+)

If you have obtained positive result, please proceed to private health screening facility, COVID-19 Assessment Centre (CAC) or government health clinics for further health assessment and actions.

Negative (-)

Continue to comply with all local applicable rules and protective measures.

Invalid

It indicates that the operation process is incorrect or the test cassette has been damaged. In this case, please read the instruction manual carefully again and retest with a new test cassette.

Disposal Procedure

After testing, put the test cassette into a biohazard bag provided and seal it tightly. Dispose the bag in the waste container.

Reporting Results

All results (positive, negative or invalid) have to be reported in COVID-19 Self Test section in MySejahtera app. You can also scan the QR code for reporting. /

Visit here for more information.

Note: A negative test result by COVID-19 self-test only indicates that proteins from the virus that causes COVID-19 were not found in your sample. It is possible for some individuals with COVID-19 to have negative result due to the amount of antigen in a sample decrease overtime. Using COVID-19 self-test after you have had symptoms for more than 7 days likely to give you a negative result compared to a molecular assay.

If you are tested negative by a COVID-19 self-test and continue to experience COVID-19-like symptoms such as fever, cough and/or shortness of breath, you should proceed to health screening facility immediately for further health assessment.

About the V-chek Test

V-Chek Test is an immunochromatography sandwich assay using double-antibody sandwich to legally detect the antigen of novel coronavirus (2019-nCoV) in nasal swab samples.

During detection, the gold labeled anti-2019-nCoV monoclonal antibody in the labeling pad binds to the 2019-nCoV antigen in the sample to form a complex. Then the reaction complex moves forward along the nitrocellulose membrane under the action of chromatography. It is captured by the anti-2019-nCoV monoclonal antibody pre-coated in the Test area (T) on the nitrocellulose membrane. Finally a red color reaction line is formed in the Test area (T).

If the sample does not contain 2019-nCoV antigen, a red color reaction line cannot be formed in the Test area (T). Regardless of whether the sample to be tested contains 2019-nCoV antigen, a red reaction line will always form in the quality control area (C), if the test has been performed properly.

This product is meant for self-testing use.

Please note: this product is currently authorized for sale or distribution in Malaysia. Referring to MDA requirement, it is strictly forbidden for individuals to sell Covid-19 RTK (self-test).

Clinical Performance

The performance of 2019-nCoV Ag Rapid Test Kit (Immunochromatography) was established with 505 Nasal (NS) swabs collected from symptomatic and asymptomatic patients.

Vchek Nasal Kit Available Now At:

Please drop us an email at [email protected] for better pricing.